{"labelingInfo":null,"renderer":{"description":"Survey Data Locations","label":"UDOT Control Point - Retaining Walls & Slopes QC","symbol":{"angle":0,"color":[255,0,0,255],"outline":{"color":[255,255,0,255],"width":1},"size":8,"style":"esriSMSCircle","type":"esriSMS","xoffset":0,"yoffset":0},"type":"simple"},"transparency":0}
HasZ: false
HasM: false
Has Attachments: true
Has Geometry Properties: false
HTML Popup Type: esriServerHTMLPopupTypeAsHTMLText
note_right_bottom2 (type: esriFieldTypeString, alias: EVC After Geotech instrumentation has been installed, SQL Type: sqlTypeOther, length: 255, nullable: true, editable: true)
note_right_bottom3 (type: esriFieldTypeString, alias: Use CP form C for Pre-Concrete placement for leveling pad, SQL Type: sqlTypeOther, length: 255, nullable: true, editable: true)
note_right_bottom4 (type: esriFieldTypeString, alias: Use CP form E for select fill lift by left placement and testing, SQL Type: sqlTypeOther, length: 255, nullable: true, editable: true)
DOC_1_Submittals_Provided (type: esriFieldTypeString, alias: DOC-1: Have all submittals required by Specification and Drawings associated with the CP been provided and meet project, SQL Type: sqlTypeOther, length: 255, nullable: true, editable: true, Coded Values: [Pass: Pass], [Fail: Fail], [NA: N/A])
DOC_2_Req_Tests_Submitted (type: esriFieldTypeString, alias: DOC-2: Have all required tests associated with this CP been completed and submitted and found to be passing?, SQL Type: sqlTypeOther, length: 255, nullable: true, editable: true, Coded Values: [Pass: Pass], [Fail: Fail], [NA: N/A])
DOC_3_Doc_Cited_Submitted (type: esriFieldTypeString, alias: DOC-3: Documentation or information cited below must be present at the CP or submitted and approved, with results known to participants., SQL Type: sqlTypeOther, length: 255, nullable: true, editable: true, Coded Values: [Pass: Pass], [Fail: Fail], [NA: N/A])
Q1_Outstanding_Issues (type: esriFieldTypeString, alias: 1: Have all outstanding issues related to the quality of work associated with this CP been resolved?, SQL Type: sqlTypeOther, length: 255, nullable: true, editable: true, Coded Values: [Pass: Pass], [Fail: Fail], [NA: N/A])
Q9_Lifts_Placed_Tested (type: esriFieldTypeString, alias: 9: Lifts placed and tested per Special Provision?, SQL Type: sqlTypeOther, length: 255, nullable: true, editable: true, Coded Values: [Pass: Pass], [Fail: Fail], [NA: N/A])
Q10_FreeDrain_Backfill (type: esriFieldTypeString, alias: 10: Is free draining backfill being plate compacted with at least three passes?, SQL Type: sqlTypeOther, length: 255, nullable: true, editable: true, Coded Values: [Pass: Pass], [Fail: Fail], [NA: N/A])
Q11_Material_Removed (type: esriFieldTypeString, alias: 11: Material that does not meet specifications removed and replaced?, SQL Type: sqlTypeOther, length: 255, nullable: true, editable: true, Coded Values: [Pass: Pass], [Fail: Fail], [NA: N/A])
Q12_Walls_Per_Plan (type: esriFieldTypeString, alias: 12:Are wall reinforcement and panels being placed per plan? Verify skews and overlaps are per plan and panels have correct batter. Document this on the MSE Wall Tolerance Tracker and attach to control point., SQL Type: sqlTypeOther, length: 255, nullable: true, editable: true, Coded Values: [Pass: Pass], [Fail: Fail], [NA: N/A])
Q13_Reinforcment (type: esriFieldTypeString, alias: 13: Are reinforcement around obstructions per plan and specification?, SQL Type: sqlTypeOther, length: 255, nullable: true, editable: true, Coded Values: [Pass: Pass], [Fail: Fail], [NA: N/A])
Q14_Embankments (type: esriFieldTypeString, alias: 14: Embankments constructed according to plan limits and finished to specified line and grade?, SQL Type: sqlTypeOther, length: 255, nullable: true, editable: true, Coded Values: [Pass: Pass], [Fail: Fail], [NA: N/A])
Q15_Panel_Alignment (type: esriFieldTypeString, alias: 15: Verify panel horizontal and vertical alignment are within tolerance. Document this on the MSE Wall Tolerance Tracker and attach to control point., SQL Type: sqlTypeOther, length: 255, nullable: true, editable: true, Coded Values: [Pass: Pass], [Fail: Fail], [NA: N/A])
Q16_Plumbness (type: esriFieldTypeString, alias: 16: Check overall wall plumbness. Document this on the MSE Wall Tolerance Tracker and attach to control point., SQL Type: sqlTypeOther, length: 255, nullable: true, editable: true, Coded Values: [Pass: Pass], [Fail: Fail], [NA: N/A])
Q17_Joint_Width_Offset (type: esriFieldTypeString, alias: 17: Verify joint width and offset. Document this on the MSE Wall Tolerance Tracker and attach to control point., SQL Type: sqlTypeOther, length: 255, nullable: true, editable: true, Coded Values: [Pass: Pass], [Fail: Fail], [NA: N/A])
Q18_Shotcrete (type: esriFieldTypeString, alias: 18: Shotcrete placed when ambient temperature is 40 degrees F or greater (Do not apply shotcrete during high winds or heavy rain), SQL Type: sqlTypeOther, length: 255, nullable: true, editable: true, Coded Values: [Pass: Pass], [Fail: Fail], [NA: N/A])
Q19_Material_Sampled (type: esriFieldTypeString, alias: 19: Material sampled and tested according to Specs?, SQL Type: sqlTypeOther, length: 255, nullable: true, editable: true, Coded Values: [Pass: Pass], [Fail: Fail], [NA: N/A])
Q20_Approved_Depth (type: esriFieldTypeString, alias: 20: Approved depth gages are installed to indicate the thickness of shotcrete layers., SQL Type: sqlTypeOther, length: 255, nullable: true, editable: true, Coded Values: [Pass: Pass], [Fail: Fail], [NA: N/A])
Q22_Welded_Wire (type: esriFieldTypeString, alias: 22: Welded wire reinforcement is not directly against the soil, provide a minimum of 1 inch of shotcrete between the soil and welded wire reinforcement., SQL Type: sqlTypeOther, length: 255, nullable: true, editable: true, Coded Values: [Pass: Pass], [Fail: Fail], [NA: N/A])
Q23_Contractors_Equipt (type: esriFieldTypeString, alias: 23: Contractors have right equipment for mixing grout and installing the grout and shotcrete., SQL Type: sqlTypeOther, length: 255, nullable: true, editable: true, Coded Values: [Pass: Pass], [Fail: Fail], [NA: N/A])
Q24_Mud_Balance (type: esriFieldTypeString, alias: 24: Was a mud balance performed on the grout mix?, SQL Type: sqlTypeOther, length: 255, nullable: true, editable: true, Coded Values: [Pass: Pass], [Fail: Fail], [NA: N/A])
Q26_Grout_Drill_Hole (type: esriFieldTypeString, alias: 26: Contractor grout the drill hole after installation of the soil nail bar and within 2 hour of completing drilling., SQL Type: sqlTypeOther, length: 255, nullable: true, editable: true, Coded Values: [Pass: Pass], [Fail: Fail], [NA: N/A])
Q31_Soil_Nail_Walls (type: esriFieldTypeString, alias: 31: SOIL NAIL WALLS - Has shotcrete cured at least 18 hours and soil nail grout obtained a minimum compressive strength of 2,000 psi before excavation of next lift?, SQL Type: sqlTypeOther, length: 255, nullable: true, editable: true, Coded Values: [Pass: Pass], [Fail: Fail], [NA: N/A])