Name: Electric Device
Display Field: assetgroup
Type: Feature Layer
Geometry Type: esriGeometryPoint
Description: Electric Distribution Device
Copyright Text:
Min. Scale: 0
Max. Scale: 0
Default Visibility: true
Max Record Count: 2000
Supported query Formats: JSON, geoJSON, PBF
Use Standardized Queries: True
Extent:
XMin: 488001.896972641
YMin: 5053803.28338138
XMax: 496912.250976301
YMax: 5060209.814606
Spatial Reference: 102059 (6341)
Vertical Spatial Reference: 105703 (6360)
Drawing Info:
{"renderer":{"authoringInfo":{"colorRamp":{"type":"multipart","colorRamps":[{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[215,252,237,255],"toColor":[215,252,237,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[251,179,252,255],"toColor":[251,179,252,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[252,185,182,255],"toColor":[252,185,182,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[182,209,252,255],"toColor":[182,209,252,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[240,252,179,255],"toColor":[240,252,179,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[252,215,242,255],"toColor":[252,215,242,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[252,231,199,255],"toColor":[252,231,199,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[182,252,182,255],"toColor":[182,252,182,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[188,182,252,255],"toColor":[188,182,252,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[192,234,252,255],"toColor":[192,234,252,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[224,202,252,255],"toColor":[224,202,252,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[252,218,215,255],"toColor":[252,218,215,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[252,182,210,255],"toColor":[252,182,210,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[218,252,207,255],"toColor":[218,252,207,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[179,252,222,255],"toColor":[179,252,222,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[252,245,189,255],"toColor":[252,245,189,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[252,184,240,255],"toColor":[252,184,240,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[194,251,252,255],"toColor":[194,251,252,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[223,184,252,255],"toColor":[223,184,252,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[214,252,184,255],"toColor":[214,252,184,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[215,222,252,255],"toColor":[215,222,252,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[252,207,182,255],"toColor":[252,207,182,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[184,252,200,255],"toColor":[184,252,200,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[252,202,242,255],"toColor":[252,202,242,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[252,194,204,255],"toColor":[252,194,204,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[241,252,215,255],"toColor":[241,252,215,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[232,252,194,255],"toColor":[232,252,194,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[194,201,252,255],"toColor":[194,201,252,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[240,215,252,255],"toColor":[240,215,252,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[179,252,245,255],"toColor":[179,252,245,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[252,215,225,255],"toColor":[252,215,225,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[202,252,217,255],"toColor":[202,252,217,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[245,189,252,255],"toColor":[245,189,252,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[212,210,252,255],"toColor":[212,210,252,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[204,192,252,255],"toColor":[204,192,252,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[252,231,215,255],"toColor":[252,231,215,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[252,201,197,255],"toColor":[252,201,197,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[192,252,235,255],"toColor":[192,252,235,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[252,192,227,255],"toColor":[252,192,227,255]}]}},"type":"uniqueValue","field1":"assetgroup","fieldDelimiter":",","uniqueValueInfos":[{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"9be2b542-c59e-4f54-a784-5b043163bfde","imageData":"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","contentType":"image/png","width":20,"height":20},"value":"0","label":"Unknown"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"83e282af-1ea6-492c-9905-847f90b31c7a","imageData":"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","contentType":"image/png","width":21,"height":21},"value":"1","label":"Ground"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"e223ce29-3016-4620-84d7-679e5fd3a2f9","imageData":"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","contentType":"image/png","width":21,"height":21},"value":"2","label":"High Voltage Arrester"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"ce246568-c541-458e-82a8-9e6aabdf704d","imageData":"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","contentType":"image/png","width":21,"height":21},"value":"3","label":"High Voltage Controller"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"75574589-9103-4d3b-970e-c7d03c938e7b","imageData":"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","contentType":"image/png","width":21,"height":21},"value":"4","label":"High Voltage Generation"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"bebae6c0-5b54-471f-ba1f-841efee1f30b","imageData":"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","contentType":"image/png","width":21,"height":21},"value":"5","label":"High Voltage Line Monitor and Relay"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"dc10b2d9-9e71-4ea8-9daa-d4fd2d9b04ee","imageData":"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","contentType":"image/png","width":21,"height":21},"value":"6","label":"High Voltage Power Conversion"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"4df8792b-0d26-4d4b-acbf-bff3b0213461","imageData":"iVBORw0KGgoAAAANSUhEUgAAABwAAAAcCAYAAAByDd+UAAAACXBIWXMAAA7EAAAOxAGVKw4bAAACxElEQVRIie2Wr3KrQBTGv80UsxgMIhiqYyKozhMkfYRIWB6jvlNTEchU9RFCX6DRjaAWtYYIDBWs2ZmcKxoySdjkpu2dqvspYHfOj/Nvz17hl3X1H9gqiqIJYywAMAYQ7C2tiSjr9Xrz2Wy2+jEwjuOQiMIjyL76jLGQiEIhxIqI7tI0zb4FFEJkRDQGAM45HMeB4ziwLAuWZQEAlFJomgZlWUJrHTDGFkKIlyRJJl8CCiEyAGPLsuB5HlzXNe7jnINzDtd1UVUVpJQAMBZCvCVJcnMRsIVxzuF5HhzHOReInVzXhW3bKIoCWusgiqI0TdPoLHCbs51nl8Jacc4xGAyQ5zkYY2EcxwfF1AFuC8QIk1KirmsMh0PjeyvLsuD7PqSUIKIMgGcERlE0ARC0OTnW6+srlsslnp6eAAB5nmOxWOD+/r7zc21OlVL9OI6D1ssD4LbPvhzGU7JtG0opbDabEEDUAeKzqVHXNbTWHQMfHx9Gw1JK41rbOq0jJmAAAA8PDxf68KnHx0fj9+l0Cs75zq4JCAAYjUZGA+/v76jr+uL9JhmB0+nUuPn5+RnL5bLz/fb21ph3rTXyPAeA9SngGkBfKdWG4kdqmqZ9LI1AIsoYY2HTNEbg9fX1QXH4vt/pwX21hUdE5sbv9XpzIgrLsjT24Wg0OsjXcDg8C6yqamfXCJzNZishxEprHVRVdfLAvkTbpgeA1d+OtjvG2EJKCdu2v5VLpVQ7NUBEd/trHWCappkQ4gXAuCgKDAaDXQNfCiuKooXNj4exsS2SJJkIId601kGe5/B9/6Lw7s1DAHg5Hk0ngVvoTRRFKWMslFKiqirYtg3XdXdh1lqjaRporfdz1nrWgZ0FAkCaplEcx3MiypRSfaXUrvJO6Gd3GuCzcgF4cRwHm80m3B7E7dm4BlAS0eqf3dqOwMYwfUW/fhH+A781cAq/kqmlAAAAAElFTkSuQmCC","contentType":"image/png","width":21,"height":21},"value":"7","label":"High Voltage Power Factor Correcting"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"d6aba86a-2842-4e8d-9f6f-8447367253c4","imageData":"iVBORw0KGgoAAAANSUhEUgAAABwAAAAcCAYAAAByDd+UAAAACXBIWXMAAA7EAAAOxAGVKw4bAAADOUlEQVRIie2WrXLjPBSGH2fWxAE1CaiJeYhBFvsKWpPywFgGYb2BXkNA4kLnDpzeQIM3QLhIxAUmIRbxTLRgK09+nO7ut98s2hd5LFuP3nN0jvSFv6wv/4BWaZreO44zAe6AydHQuzFmMxgMnpfL5e6PgVmWzYwxszPIsW4dx5kZY2ZCiJ0x5inP881/AgohNsaYOwDP8/B9H9/3cV0X13UB0FrTNA1VVdG27cRxnFII8bJare5/CyiE2AB3rusSBAGj0aj3O8/z8DyP0WhEXdcopQDuhBDfVqvV118CWpjneQRBgO/7J+P7/R6lFFEUASClZL1edwt4eHigbdtJmqZ5nufpp8CPnHXOzmEAvu+zXq87YBRFSCnZbrcAjMdjpJQ4jjPLsuxkM10APzbIVZhVHMdst1viOO5gURShlMJ1XcIwRCmFMWYDBL3ANE3vgYnNyWeKoojFYsHNzQ2LxYIkSUiSBCklQJdTrfVtlmUT6/IE+FFnvc7KsiRJkl6ohdl3VsPhEK01h8NhBqQXQH4U9dW8PT4+kiRJF8aiKAjD8GIhVtalNdIHnABdjR3LQmwIpZQkSUIURV0uz+V53sm8fUCuAQGSJKEsS6SUxHHclcbr62svsE9XC78oCnzfPwnXfr/vnNn32+0W3/d7XbZtax/frwHfgVutNdPpFKUUi8WCKIq6UJ5PGscxcRxTFMXFWNM09rHqBRpjNo7jzJqmwfM8wjBkPp9TliVFURBFEdPplKIoUEoRhmH373Q6vYiSdWiM6S/8wWDwbIyZVVXV1aGUsisJ3/c7x2VZMp/PLyDHquu6m7cXuFwud0KIXdu2k7quqarqos5sh1FKXbg8h2mtAXY/a21PjuOUSinquj6BWdm8SSl7gVpre2pgjHk6HrsA5nm+EUK8AHdBEDAej3sdwGlXOYa9vb1Z2PP5YdxbFqvV6l4I8a1t24l18bPeChyfhwAv50fTVeAH9GuaprnjODMb3uFwyGg06jpI27Y0TUPbtsc5s84uYJ8CAfI8T7MsezbGbLTWt1rrbudd0Z/daeDHzgWCLMsmh8Nh9tGIbW98BypjzO5/u7WdgXvD9Dv66xfh7yGEyS/elQn7AAAAAElFTkSuQmCC","contentType":"image/png","width":21,"height":21},"value":"8","label":"High Voltage Regulator"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"62cba530-214b-4fcc-b557-3068d7bf56d2","imageData":"iVBORw0KGgoAAAANSUhEUgAAABwAAAAcCAYAAAByDd+UAAAACXBIWXMAAA7EAAAOxAGVKw4bAAADh0lEQVRIie2Wr3biShzHP+EsZhDERBQTj+gIVocXoLwBSJIIHgHRg62LgFTSN4C+QNGLCBY1hgpMKhiTc5grluQQSHvv3r1n1f2qBH6Zz/z+znzjD+vb/8Bcvu8/WJbVAXpA5+Kvd2PMqlarPc9ms81vA8MwHBljRleQS91ZljUyxoyCINgYYx7jOF79K2AQBCtjTA9ACIFt29i2Tb1ep16vA6C15ng8st/vybKsY1nWMgiC1/l8/vBLwCAIVkCvXq/TarVwHKfSTgiBEALHcTgcDiilAHpBEPyYz+ff/xEwhwkhaLVa2LZ9Y6OUIooi7u/vGQ6HADiOQ6PRYLfbkWVZx/f9OI5j/0vgOWeFZ7Zto5Si2WzegNM0Zb1es91uGQwGSCkRQtBut0mSBMuyRmEYlorpBngukBJsuVySJAlPT08lqOu69Pt9oigiiiKklIzHY+r1Oq7ropTCGLMCWpVA3/cfgE6ekzRNC1i/368MrZSSyWRCFEUkSYJSCtd1i5xqre/CMOzkXpaA5z4rFt5utyRJgud59Pv9UiibzWaRO9d1GY/HTKdTFosFk8kEgEajgdaa0+k0AvyqkPYugWmaAtDtdktG6/X6xmPXdQHyKgUovMwdqQJ2gKLHkiQBoNlslozyYvE8r/S7lLL4Bn62zOW6VUAugR8fH1x6nKvb7bJYLG6AruuWgFX6ctK4rkuapqRpehM+KeWNfZIkRWgBsizLH98/A74Dd1prhBBFKPOcXer6XSmFUqrk9fF4zB/3lUBjzMqyrNHxeEQIwXA4ZLvdslwukVKWdn+t5XKJbdulAss9NMZUN36tVns2xoz2+30xOweDAVEUMZ1OGQ6HN3m7HAzD4bC0qcPhUKxbCZzNZpsgCDZZlnUOhwOO4xTT4+XlhcViwWKxKPKXpilKKWzbvtnMuekBNn832h4ty1oqpWg0GgghkFIipWS9XvP29lZUouu6eJ5Ht9steaa1LvrRGPN4uf4NMI7jVRAEr0Bvt9vRbreLNvE87yak19Jas9vtctjz9WFc2Rbz+fwhCIIfWZZ18lL/7Dy81MV5CPB6fTR9CjxDv/u+H1uWNVJKcTgcaDQaOI5TTJAsyzgej2RZdpmz3LMb2JdAgDiO/TAMn40xK631nda6qLxP9Ht3GvhZuUArDMPO6XQanQdxPhvfgb0xZvOf3dquwJVh+hX98YvwX/nI3MTo147TAAAAAElFTkSuQmCC","contentType":"image/png","width":21,"height":21},"value":"9","label":"High Voltage Service"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"3c7d34ba-f795-4e9a-8635-a331492904eb","imageData":"iVBORw0KGgoAAAANSUhEUgAAABwAAAAcCAYAAAByDd+UAAAACXBIWXMAAA7EAAAOxAGVKw4bAAACvUlEQVRIie2WrXbqQBSF97AaMzExEcREgygi+L4A9A1qk4ngIfoMFSTIPkLTF2g1iJiaqJggYqhgzKzFuaJMbiA/pe1dVXc71kz41vnZ58wVfllX/4FaQRDMGWMegBkAr3a0JaJkMBislsvl5sfAMAx9IvLPIHUNGWM+EflCiA0R3cdxnHwLKIRIiGgGAJxzWJYFy7JgGAYMwwAASCmx3+9RFAWUUh5j7EkI8RxF0fxLQCFEAmBmGAYcx4Ft2633OOfgnMO2bZRliTzPAWAmhFhHUTS9CKhhnHM4jgPLsvoSUcm2bZimiSzLoJTygiCI4zgOeoHHmlWRXQrT4pxjPB4jTVMwxvwwDE+aqQE8Nsi3YFqGYcB1XeR5DiJKADitwCAI5gA8XZMupWkKAJhMJp13dE2llMMwDD0d5Qnw6LPeyNI0xcPDAwBgsVj0Qk3ThJQSh8PBBxA0gPgwdSewDptMJr0w4G+UOpA2oFeWJd7e3iqfab2/v+Px8bGCLRYLAECe59jtdr1g1IZGo2nW67X2UqvqMAB4eXnB6+tr530hxMnvBtA0zc6PXdfF3d1d5/m5HKdqzm0XcDudToej0agVfH193ajv7e0tbm5uWoG73Q5KKQAoWoFElHDO/dFo1GuLuvR8bRPnXHux3fiDwWBFRH5RFBcD+1SWZfW/rcDlcrkRQmyUUl5Zlj+CHk0PAJvPRts9Y+wpz3OYpgnO+ZdhUsqq04novn7WAMZxnAghngHMsizDeDxuePIzWJZlGrY6X8at6ymKorkQYq2U8tI0heu6F6W3tg8B4Pl8NXUCj9BpEAQxY8zP8xxlWcI0Tdi2XaVZKYX9fg+lVL1mOrIGrBcIAHEcB2EYrogokVIOpZRV53XoZ28a4KNzAThhGHqHw8E/DmI9G7cACiLa/LNX2xm4NU1f0a8/hP8AFKtePUQrPx4AAAAASUVORK5CYII=","contentType":"image/png","width":21,"height":21},"value":"10","label":"High Voltage Switch"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"5780cfbc-cd3d-4d51-811b-29b4cf95f099","imageData":"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","contentType":"image/png","width":21,"height":21},"value":"11","label":"High Voltage Transformer"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"c51cd1b3-2b76-4dac-afbe-216ed1f1d28c","imageData":"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","contentType":"image/png","width":21,"height":21},"value":"12","label":"Low Voltage Arrester"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"f15ae38a-b537-446a-a353-fed049b0b3b8","imageData":"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","contentType":"image/png","width":20,"height":20},"value":"13","label":"Low Voltage Controller"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"2718acd1-57e1-441c-bb17-9dd4a65b6f01","imageData":"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","contentType":"image/png","width":21,"height":21},"value":"14","label":"Low Voltage Fuse"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"c04c93c2-db80-45df-a160-66d38845c576","imageData":"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","contentType":"image/png","width":20,"height":20},"value":"15","label":"Low Voltage Generation"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"91bcdd5d-80f1-4bcd-bdc0-3970d2ccb832","imageData":"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","contentType":"image/png","width":21,"height":21},"value":"16","label":"Low Voltage Lighting"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"f329dfcc-4370-41de-8ac1-5633a3d97271","imageData":"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","contentType":"image/png","width":21,"height":21},"value":"17","label":"Low Voltage Line Monitor and Relay"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"fe6b22f6-496f-4b90-8fd9-c3bcb93d5ed8","imageData":"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","contentType":"image/png","width":21,"height":21},"value":"18","label":"Low Voltage Motor"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"b865b25d-17bf-4691-af9e-ba632b74f671","imageData":"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","contentType":"image/png","width":20,"height":20},"value":"19","label":"Low Voltage Network Protection"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"d2c9bac6-65f3-4865-84e4-5328c8b9d98e","imageData":"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","contentType":"image/png","width":21,"height":21},"value":"20","label":"Low Voltage Power Conversion"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"09a03cb4-3ab6-41cd-9c22-e6af2ff1ee05","imageData":"iVBORw0KGgoAAAANSUhEUgAAABwAAAAcCAYAAAByDd+UAAAACXBIWXMAAA7EAAAOxAGVKw4bAAACnUlEQVRIie2WP3LiMBSHP89sj1tTRDeAwlv7BCg3oOKNcwFKZpLcwQ0ZUXkmB0A5get17qAicWuaNCm8BRZrsMnA7s5W+6sQ8ujT+6f3vvGP9e0/0GuxWOggCGJgBsSdrQqwwJMxpvxjoIikQHoC6Spq91MRKZumedxsNva3gCJi2VuEUorpdMpkMiEMQ0ajEQDOOZxzWGup6zoOgmArIi/GGH0V0MPCMERrTZIkg98ppVBKkSQJRVGQ5znATER+GGO+XwT0MKUUt7e3TCaTrxxxUJIkKKXIsoy6rmMRWRtj7r4EtjGbhWF4FcxLKcVqtWK5XMI+rkfJNGRhCqC1PoJVVUVZlsRxTBRFvXVXo9GI+Xzu3WuB8SBwsVhoIPYx6er9/R2tNQ8PD9zf3+MvlaYp6/W6d2sfU+dcJCKxt/II2NYZ0+l02F9XSimFcw72XrvrAYHZx8cHn5+flOVxDZ+uvbxrh+StpFPDp8D49fWV5+fni62w1mJtv87H4zFvb2+Hc88Bubm5Gay5qqoGD9Za95LGA4c0CBxKgrIsB4FRFA1+D7Db7Q73PQesgMg5h1Jq8JBr1CYMwPs5oAXSIeB4PD5yXxRFaK3Pug6grmv/82zhPwGptbYXxyiK2G63R/+drk/VZqg/tw80xpQiUtZ1HRdFcfbBvkRt0QOUXz5tTdM8BkGwzfP80AmulXPOP2s0TfPY3esBN5uNFZEXYJZlGavV6tD7LoVlWeaXT6fNeLA9GWO0iPyo6zpeLpfM5/OL3NvphwAvp63pLLCFfheRNZDmeU5RFIdG69282+1wzlHXdTdmsJ9verAvgS30TkSeAOuci5xz3cwb0p/NNC20BMYiEvNrmPJvY8W+qEv+1tR2Ah500zX654PwT7C7SD7hbrW3AAAAAElFTkSuQmCC","contentType":"image/png","width":21,"height":21},"value":"21","label":"Low Voltage Power Factor Correcting"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"0cf7f86e-2f16-4aec-83ef-68a868afbc6f","imageData":"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","contentType":"image/png","width":21,"height":21},"value":"22","label":"Low Voltage Service"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"14055b5a-34ea-4857-8f21-a400e411c899","imageData":"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","contentType":"image/png","width":21,"height":21},"value":"23","label":"Low Voltage Switch"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"05fe9f58-da69-44ea-aa83-470b9dc76d71","imageData":"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","contentType":"image/png","width":21,"height":21},"value":"24","label":"Low Voltage Transformer"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"0b9843cc-a056-48b7-bbaa-01c0d9f1f8bc","imageData":"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","contentType":"image/png","width":21,"height":21},"value":"25","label":"Medium Voltage Arrester"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"793bd896-3fc7-4eba-9f43-b9f5fdd51a7e","imageData":"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","contentType":"image/png","width":20,"height":20},"value":"26","label":"Medium Voltage Circuit Breaker"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"c61222de-2868-46b2-8557-ea4fd6422f31","imageData":"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","contentType":"image/png","width":21,"height":21},"value":"27","label":"Medium Voltage Controller"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"160387f8-2b0c-4c87-9b5e-4d03678c6ce4","imageData":"iVBORw0KGgoAAAANSUhEUgAAABwAAAAcCAYAAAByDd+UAAAACXBIWXMAAA7EAAAOxAGVKw4bAAAC2UlEQVRIie2WvW7iQBSFv2ut5G4qIMriio6CyhvxAEmZvEBabKdNypR5jM2Yl1gok4Y2i0TnDimSvatQTjcNs0WwFYJhYf+qPeV4PJ/vmbln/IF/rA//gaXSNL1wzoUicg6E5bhz7rvneaPlcnkfx/H0t4Fa60REEiAUkY3nInLsnEtEJEnTdArcRVE0+iWg1nq0qgilFM1mk0ajge/7+L4PgDEGYwzz+RxrbQh80VqP4zi+OAhYwnzfp9PpEARB7TylFEopgiAgz3OyLENEztM0/RpF0ae9gCVMKUWn06HZbO4yolIQBCilmM1mWGvD4XD4eTAYXO0ErvasqmxfWCmlFP1+n8lkgnMu0VqvHaYN4OqAVLDFYsHt7e1WwPX1Nb1eb23M93263S5ZlgGMgI+1wDRNL4Cw3BOAl5cXHh4etgIvLy9rx4MgoCgKjDHHWuuwrHINuOqzg218fHysPurs7IzT01Pg1V5jDJ7nJcDVBrBsgUajcRAQ4OjoCHh1pFS73SbPc5xzVVC838MQqHpsm97a2Gq16PV6VVVvpZRaW7cOyD7Am5sbWq3Wzjnb9FfD21oLvOZtLdA5911Ejo0xb+3YOPb7yhgDgIh8qwV6njdyziVvgb1ej/F4DMBisTjIyrJCEalv/OVyeS8iyXw+38jOxWLByckJz8/PewOLoqjWrQXGcTxN03RqrQ3zPN8a2Psoz/PS0unOaAPugC9ZllU3waEyxpSxVq5XaQMYRdFIaz0WkfPZbEa/38f3fVqtFk9PT3vBZrMZACJyPxgM1i7j2raI4/giTdOv1tpwMpnQ7XYJguCnB6a8DwGcc+Moiq7ez9nah1EUfRoOh5+dc0mWZRRFgVKKdrtd2WytxRiDtbYM6qqyOthOIMBgMLjSWt8DI2PMsTGGPM93vTIF7t7buDcQXk8u8FFrHXqel6yCOIQqKL6JyPSP/bW9A9fadIj++Y/wD+/0UEsJi2jNAAAAAElFTkSuQmCC","contentType":"image/png","width":21,"height":21},"value":"28","label":"Medium Voltage Elbow"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"591fcf1d-2662-4973-b114-f77957839b5b","imageData":"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","contentType":"image/png","width":21,"height":21},"value":"29","label":"Medium Voltage Fuse"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"2bce514a-009b-4401-813f-fee9b6713327","imageData":"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","contentType":"image/png","width":21,"height":21},"value":"30","label":"Medium Voltage Generation"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"a2477854-a182-487b-8c82-4273badbba7d","imageData":"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","contentType":"image/png","width":21,"height":21},"value":"31","label":"Medium Voltage Line Monitor and Relay"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"e30c895b-99dc-48b2-b28e-dfee312a66e2","imageData":"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","contentType":"image/png","width":21,"height":21},"value":"32","label":"Medium Voltage Motor and Pump"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"67bc1f83-0a0a-4a23-a2ab-b4d92cbe8721","imageData":"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","contentType":"image/png","width":21,"height":21},"value":"33","label":"Medium Voltage Power Conversion"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"0f99031c-9473-4759-b680-5c7e88abb564","imageData":"iVBORw0KGgoAAAANSUhEUgAAABwAAAAcCAYAAAByDd+UAAAACXBIWXMAAA7EAAAOxAGVKw4bAAAC5ElEQVRIie2Wv27iQBDGv7EiWWm2CpFIXNFRpHIkHoCU4QUo4z+pU6ZMRZk67NL6AUJaGtoEyRKFO6RIdlAoV0qxDXtFWOuABZm7U6r7Oi/D/jzf7sz4CD+so/9AIyFER2vtE9E1AN+sa63njuMMl8tlP4qiyV8DOecxEcUAfCLa+p2I6lrrmIhiIcQEwEMYhsM/AnLOh6uMwBhDrVbDyckJXNeF67oAACklpJSYzWZQSvkAnjnnL1EUdQ4CGpjrumg0GvA8zxrHGANjDJ7nIc9zZFkGIroWQryFYXhZCWhgjDE0Gg3UarV9RpTyPA+MMaRpCqWUPxgMnoIguN0LXJ1ZmVlVmBFjDK1WC+PxGFrrmHO+dpm2gKsLYoVNp1MsFgu0223rs5Hrumg2m8iyDACGAM6sQCFEB4BvzmRTSZIgSRK8v78DAEajER4fH/H6+orT09O1WM/zUBQFpJR1zrlvslwDrursYBt3iTEGKSUcx4kB3G4BTQnM53N8fX1tbbBYLKwbT6fTrQwB4Pj4GMB3ImZt8wx9AOh2u9XTAHBzc2Nd7/V6xq2dQOwDjkYjfH5+Vo63yQrs9XrW4Pv7eyRJsrV+d3dntVQpZcpjbgVqredEVJdSgjFW+a13SUoJACCiDyvQcZyh1jreBby4uMDV1dXO500ppQzQXvjL5bJPRPFsNrPWYbfbXTuvdru9VfS/qyiKcl8rMIqiiRBiopTy8zzf2bCrKM9zY+lkb2sD8ADgOcuychIcKimlaWtmv1JbwDAMh5zzFyK6TtMUrVarnH1VYWmaAgCIqB8EwdowtpZFFEUdIcSbUsofj8doNpuV7DXzEAC01i9hGN5uxuwcwGEYXg4GgyetdZxlGYqiAGMM5+fnpc1KKUgpoZQyjbrMzAbbCwSAIAhuOed9AEMpZV1KiTzP9/1lAuBh08bKQOD75gI445z7juPEq0bsA2Wj+CCiyT/7atsAW206RD/+IfwLpbxi6uEfRtAAAAAASUVORK5CYII=","contentType":"image/png","width":21,"height":21},"value":"34","label":"Medium Voltage Power Factor Correcting"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"ea3309fc-88d8-44c1-abaf-429041d42ed1","imageData":"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","contentType":"image/png","width":21,"height":21},"value":"35","label":"Medium Voltage Regulator"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"ac554214-5848-4d10-8e28-4c8d771e5ab1","imageData":"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","contentType":"image/png","width":21,"height":21},"value":"36","label":"Medium Voltage Service"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"e977a2c5-faed-4eea-bf6c-82e3fecc83b0","imageData":"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","contentType":"image/png","width":21,"height":21},"value":"37","label":"Medium Voltage Switch"},{"symbol":{"angle":0,"xoffset":0,"yoffset":0,"type":"esriPMS","url":"50815d4f-1998-44c2-9ab8-ec50abf5bc0d","imageData":"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","contentType":"image/png","width":21,"height":21},"value":"38","label":"Medium Voltage Transformer"}]},"transparency":0}
HasZ: true
HasM: true
Has Attachments: false
Has Geometry Properties: false
HTML Popup Type: esriServerHTMLPopupTypeAsHTMLText
Object ID Field: objectid
Unique ID Field:
IsSystemMaintained : True
Global ID Field: GlobalID_2
Type ID Field: assetgroup
Fields:
- objectid (type: esriFieldTypeOID, alias: Object ID, SQL Type: sqlTypeOther, length: 0, nullable: false, editable: false)
- assetgroup (type: esriFieldTypeInteger, alias: Asset group, SQL Type: sqlTypeOther, nullable: false, editable: true)
- assettype (type: esriFieldTypeSmallInteger, alias: Asset type, SQL Type: sqlTypeOther, nullable: false, editable: true)
- associationstatus (type: esriFieldTypeSmallInteger, alias: Association status, SQL Type: sqlTypeOther, nullable: false, editable: false, Coded Values: [0: None], [1: Container], [2: Structure], ... 18 more ...)
- issubnetworkcontroller (type: esriFieldTypeSmallInteger, alias: Is subnetwork controller, SQL Type: sqlTypeOther, nullable: false, editable: false, Coded Values: [0: False], [1: True])
- isconnected (type: esriFieldTypeSmallInteger, alias: Is connected, SQL Type: sqlTypeOther, nullable: false, editable: false, Coded Values: [0: False], [1: True], [2: Unknown])
- subnetworkcontrollername (type: esriFieldTypeString, alias: Subnetwork controller name, SQL Type: sqlTypeOther, length: 2000, nullable: false, editable: false)
- tiername (type: esriFieldTypeInteger, alias: Tier name, SQL Type: sqlTypeOther, nullable: false, editable: false, Coded Values: [0: Unknown], [1: Electric Generation Station], [2: Electric Transmission Station], ... 8 more ...)
- tierrank (type: esriFieldTypeInteger, alias: Tier rank, SQL Type: sqlTypeOther, nullable: false, editable: false)
- terminalconfiguration (type: esriFieldTypeString, alias: Terminal path, SQL Type: sqlTypeOther, length: 128, nullable: false, editable: true)
- creationdate (type: esriFieldTypeDate, alias: Creation date, SQL Type: sqlTypeOther, length: 8, nullable: true, editable: false)
- creator (type: esriFieldTypeString, alias: Creator, SQL Type: sqlTypeOther, length: 255, nullable: true, editable: false)
- lastupdate (type: esriFieldTypeDate, alias: Last update, SQL Type: sqlTypeOther, length: 8, nullable: true, editable: false)
- updatedby (type: esriFieldTypeString, alias: Updated by, SQL Type: sqlTypeOther, length: 255, nullable: true, editable: false)
- globalid (type: esriFieldTypeGUID, alias: Global ID, SQL Type: sqlTypeOther, length: 38, nullable: false, editable: false)
- assetid (type: esriFieldTypeString, alias: Asset Identifier, SQL Type: sqlTypeOther, length: 64, nullable: true, editable: true)
- plandevicestatus (type: esriFieldTypeSmallInteger, alias: Planning Device Status, SQL Type: sqlTypeOther, nullable: true, editable: true)
- normaldevicestatus (type: esriFieldTypeSmallInteger, alias: Normal Device Status, SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [0: Unknown], [1: Open], [2: Closed])
- currentdevicestatus (type: esriFieldTypeSmallInteger, alias: Current Status, SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [0: Unknown], [1: Open], [2: Closed])
- winterdevicestatus (type: esriFieldTypeSmallInteger, alias: Winter State, SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [0: Unknown], [1: Open], [2: Closed])
- summerdevicestatus (type: esriFieldTypeSmallInteger, alias: Summer State, SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [0: Unknown], [1: Open], [2: Closed])
- phasesnormal (type: esriFieldTypeSmallInteger, alias: Phases Normal, SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [0: DeEnergized], [1: C], [2: B], ... 5 more ...)
- phasescurrent (type: esriFieldTypeSmallInteger, alias: User Assigned Phases, SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [0: DeEnergized], [1: C], [2: B], ... 5 more ...)
- phasessummer (type: esriFieldTypeSmallInteger, alias: Summer Configuration Phases, SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [0: DeEnergized], [1: C], [2: B], ... 5 more ...)
- phaseswinter (type: esriFieldTypeSmallInteger, alias: Winter Configuration Phases, SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [0: DeEnergized], [1: C], [2: B], ... 5 more ...)
- phasesplan (type: esriFieldTypeSmallInteger, alias: Planned Phases, SQL Type: sqlTypeOther, nullable: true, editable: true)
- phasesenergized (type: esriFieldTypeSmallInteger, alias: Phases Propagated, SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [0: DeEnergized], [1: C], [2: B], ... 5 more ...)
- phasessubstituted (type: esriFieldTypeInteger, alias: Phases Substituted, SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [0: De-energized], [1: AB --> DD], [2: ABC --> BDD], ... 31 more ...)
- phasefrequency (type: esriFieldTypeSmallInteger, alias: Phase Frequency, SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [0: Unknown], [50: 50 hz], [60: 60 hz])
- numphasesconstructed (type: esriFieldTypeSmallInteger, alias: Number of phases built, SQL Type: sqlTypeOther, nullable: true, editable: true, Range: [0 - 3])
- designtype (type: esriFieldTypeSmallInteger, alias: Fuel Type, Type, SQL Type: sqlTypeOther, nullable: true, editable: true)
- grounding (type: esriFieldTypeSmallInteger, alias: Circuit Grounding or Earthing, Configuration - GY, Y or D, SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [0: Unknown], [1: Delta], [2: Wye])
- manufacturer (type: esriFieldTypeSmallInteger, alias: Manufacturer, SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [0: Unknown], [1: ABB/Westinghouse], [2: American Electric Lighting], ... 56 more ...)
- nominalvoltage (type: esriFieldTypeInteger, alias: Nominal Operation Voltage (L-L), SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [0: Unknown], [120: 120 V], [125: 125 V], ... 35 more ...)
- powerrating (type: esriFieldTypeInteger, alias: Average Load (kW), Power Rating, SQL Type: sqlTypeOther, nullable: true, editable: true)
- addpowerrating (type: esriFieldTypeInteger, alias: Active Generation, DC Voltage Reference Setting, KVAR, Nominal Discharge Current, Rated Current, Rated DC Voltage, Rated KVA, SQL Type: sqlTypeOther, nullable: true, editable: true)
- powermeasure (type: esriFieldTypeDouble, alias: Load Tap Changer Maximum Change (%), SQL Type: sqlTypeOther, nullable: true, editable: true)
- maxvoltage (type: esriFieldTypeInteger, alias: Maximum Voltage, SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [0: Unknown], [120: 120 V], [125: 125 V], ... 35 more ...)
- maxoperatingvoltage (type: esriFieldTypeInteger, alias: Maximum Operating Voltage, SQL Type: sqlTypeOther, nullable: true, editable: true)
- compatibleunit (type: esriFieldTypeString, alias: Compatible Unit Code, SQL Type: sqlTypeOther, length: 255, nullable: true, editable: true)
- powerrating2 (type: esriFieldTypeInteger, alias: High Impulse Current , Maximum Interrupting Current, Nominal Rating, Rated Capacity, Rated Power, Rated kVA, VSC Rating, kW-Phase, SQL Type: sqlTypeOther, nullable: true, editable: true)
- lifecyclestatus (type: esriFieldTypeSmallInteger, alias: Lifecycle Status, SQL Type: sqlTypeOther, nullable: false, editable: true, Coded Values: [0: Unknown], [1: Proposed], [2: Approved], ... 15 more ...)
- remotecontrol (type: esriFieldTypeSmallInteger, alias: Device Remotely Controlled, SQL Type: sqlTypeOther, nullable: true, editable: true)
- model (type: esriFieldTypeString, alias: Device Model, SQL Type: sqlTypeOther, length: 255, nullable: true, editable: true)
- loadtapchangermaximumchange (type: esriFieldTypeDouble, alias: Load Tap Changer Maximum Change, SQL Type: sqlTypeOther, nullable: true, editable: true)
- loadtapchangerlowerbandwidth (type: esriFieldTypeDouble, alias: Load Tap Changer Lower Bandwidth, SQL Type: sqlTypeOther, nullable: true, editable: true)
- maximumboost (type: esriFieldTypeDouble, alias: Maximum Boost, SQL Type: sqlTypeOther, nullable: true, editable: true)
- z0psimpedance (type: esriFieldTypeDouble, alias: Sequence Impedance -Z0ps (%), SQL Type: sqlTypeOther, nullable: true, editable: true)
- z0xmimpedance (type: esriFieldTypeDouble, alias: Sequence Impedance -Z0xm (%), SQL Type: sqlTypeOther, nullable: true, editable: true)
- z1psimpedance (type: esriFieldTypeDouble, alias: Sequence Impedance -Z1 (%), SQL Type: sqlTypeOther, nullable: true, editable: true)
- x0r0impedance (type: esriFieldTypeDouble, alias: Sequence Impedance -X0/R0pm, SQL Type: sqlTypeOther, nullable: true, editable: true)
- x1r1impedance (type: esriFieldTypeDouble, alias: Sequence Impedance -X1/R1, SQL Type: sqlTypeOther, nullable: true, editable: true)
- z0pmimpedance (type: esriFieldTypeDouble, alias: Sequence Impedance -Z0pm (%), SQL Type: sqlTypeOther, nullable: true, editable: true)
- primarygroundimpedance (type: esriFieldTypeDouble, alias: Primary Ground Impedance (ohms), Primary Ground Impedance Rg (ohms), SQL Type: sqlTypeOther, nullable: true, editable: true)
- gridsidecouplinginductance (type: esriFieldTypeDouble, alias: Grid Side Coupling Inductance (ohms), Primary Ground Impedance Rg (ohms), SQL Type: sqlTypeOther, nullable: true, editable: true)
- powerrating3 (type: esriFieldTypeInteger, alias: Amperage, CT Primary Rating, Rated Voltage (KV L-L), SQL Type: sqlTypeOther, nullable: true, editable: true)
- powerrating4 (type: esriFieldTypeInteger, alias: No Load Losses W, Tuned Frequency, Zero Sequence Subtransient (R+X), SQL Type: sqlTypeOther, nullable: true, editable: true)
- powerrating5 (type: esriFieldTypeInteger, alias: longelectric3, SQL Type: sqlTypeOther, nullable: true, editable: true)
- remotecontrollerindicator (type: esriFieldTypeSmallInteger, alias: Remote Control Indicator, SQL Type: sqlTypeOther, nullable: true, editable: true)
- equipmentyype (type: esriFieldTypeSmallInteger, alias: ANSI Group 2,3,4,5, Insulation Type (Liquid,Dry), Type, Type (kVA-PF, AMP-PF, kW-PF, kW-kVAR), Type of Data, SQL Type: sqlTypeOther, nullable: true, editable: true)
- tripmode (type: esriFieldTypeSmallInteger, alias: Single Phase Trip and Lockout, SQL Type: sqlTypeOther, nullable: true, editable: true)
- tapsandpoles (type: esriFieldTypeSmallInteger, alias: Number of Taps, SQL Type: sqlTypeOther, nullable: true, editable: true)
- equipmentconfiguration3 (type: esriFieldTypeSmallInteger, alias: Master Offset, Primary to Tertiary Phase Shift, SQL Type: sqlTypeOther, nullable: true, editable: true)
- equipmentconfiguration1 (type: esriFieldTypeSmallInteger, alias: Reverse Trips, SQL Type: sqlTypeOther, nullable: true, editable: true)
- nominalvoltagelg (type: esriFieldTypeInteger, alias: Nominal Operation Voltage (L-G), SQL Type: sqlTypeOther, nullable: true, editable: true)
- directional (type: esriFieldTypeSmallInteger, alias: Bi Directional, Reversible, SQL Type: sqlTypeOther, nullable: true, editable: true)
- alternatevoltagelinetoline (type: esriFieldTypeInteger, alias: Low Side Voltage (L-L), SQL Type: sqlTypeOther, nullable: true, editable: true)
- alternatevoltagelinetoground (type: esriFieldTypeInteger, alias: Low Side Voltage (L-G), SQL Type: sqlTypeOther, nullable: true, editable: true)
- electricdecimal1 (type: esriFieldTypeDouble, alias: Boost, CT Ratio, Capacitive Reactance (Ohms), Efficiency %, Grid Side coupling resistance, Maximum Boost, SQL Type: sqlTypeOther, nullable: true, editable: true)
- electricdecimal2 (type: esriFieldTypeDouble, alias: Buck, Current Maximum Power Point (Impp), DC Capacitor, DC Voltage Control, Maximum Buck, SQL Type: sqlTypeOther, nullable: true, editable: true)
- equipmentconfiguration2 (type: esriFieldTypeSmallInteger, alias: Primary to Secondary Phase Shift, Time Delay, Trip Count, SQL Type: sqlTypeOther, nullable: true, editable: true)
- electricdecimal3 (type: esriFieldTypeDouble, alias: Current Control, Fault Contribution, Inductance, Load Tap Changer Upper Bandwidth (%), PT Ratio, SQL Type: sqlTypeOther, nullable: true, editable: true)
- electricdecimal4 (type: esriFieldTypeDouble, alias: Inductive Resistance, Power Factor, Primary Ground Impedance Xg (ohms), Reactive Power Control, SQL Type: sqlTypeOther, nullable: true, editable: true)
- electricdecimal5 (type: esriFieldTypeDouble, alias: Losses (kW/Phase), The tertiary base voltage, SQL Type: sqlTypeOther, nullable: true, editable: true)
- electricdecimal6 (type: esriFieldTypeDouble, alias: Load Tap Changer Lower Bandwidth (%), Quality Factor, SQL Type: sqlTypeOther, nullable: true, editable: true)
- peakload (type: esriFieldTypeInteger, alias: Peak Load, Peak Load (kW), SQL Type: sqlTypeOther, nullable: true, editable: true)
- offpeakload (type: esriFieldTypeInteger, alias: Load at Off Peak Time, SQL Type: sqlTypeOther, nullable: true, editable: true)
- district (type: esriFieldTypeString, alias: District, SQL Type: sqlTypeOther, length: 255, nullable: true, editable: true)
- installdate (type: esriFieldTypeDate, alias: Date Installed, SQL Type: sqlTypeOther, length: 8, nullable: true, editable: true)
- retireddate (type: esriFieldTypeDate, alias: Date Retired, SQL Type: sqlTypeOther, length: 8, nullable: true, editable: true)
- inservicedate (type: esriFieldTypeDate, alias: Date Placed in Sevice, SQL Type: sqlTypeOther, length: 8, nullable: true, editable: true)
- isvalidloop (type: esriFieldTypeSmallInteger, alias: Is Loop Valid, SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [0: Unknown], [1: Yes], [2: No])
- spatialsource (type: esriFieldTypeSmallInteger, alias: Spatial Source, SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [0: Unknown], [1: As-Built], [2: CAD], ... 3 more ...)
- spatialconfidence (type: esriFieldTypeSmallInteger, alias: Spatial Confidence, SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [0: Unknown], [1: High], [2: Medium], ... 1 more ...)
- ownedby (type: esriFieldTypeSmallInteger, alias: Device Owned by, SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [1: Our Agency], [2: Private], [100: Other])
- maintby (type: esriFieldTypeSmallInteger, alias: Device Maintained by, SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [1: Our Agency], [2: Private], [100: Other])
- notes (type: esriFieldTypeString, alias: General Notes, SQL Type: sqlTypeOther, length: 2000, nullable: true, editable: true)
- symbolrotation (type: esriFieldTypeSmallInteger, alias: Symbol Rotation, SQL Type: sqlTypeOther, nullable: false, editable: true, Range: [0 - 359])
- subnetworkname (type: esriFieldTypeString, alias: Subnetwork name, SQL Type: sqlTypeOther, length: 2000, nullable: false, editable: false)
- GlobalID_2 (type: esriFieldTypeGlobalID, alias: GlobalID_2, SQL Type: sqlTypeOther, length: 38, nullable: false, editable: false)
Types:
ID: 0
Name: Unknown
Domains:
- Field Name: assettype
Coded Values:[0: Unknown]
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: Unknown
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 0
- assettype: 0
- maintby: 1
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- lifecyclestatus: 8
ID: 1
Name: Ground
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [1: Bound], [2: Rod], More
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: normaldevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: currentdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: winterdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: summerdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: Ground
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 1
- assettype: 0
- maintby: 1
- plandevicestatus: 3
- normaldevicestatus: 3
- currentdevicestatus: 3
- winterdevicestatus: 3
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 3
- lifecyclestatus: 8
ID: 2
Name: High Voltage Arrester
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [21: HV Indoor Arrester], [22: HV Line Arrester], More
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: normaldevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: currentdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: winterdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: summerdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: phasesnormal
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasescurrent
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasessummer
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phaseswinter
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasesplan
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasesenergized
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Coded Values:[0: Unknown], [2: 2], [3: 3], More
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Coded Values:[0: Unknown], [115000: 115 kV], [138000: 138 kV], More
- Field Name: maxvoltage
Coded Values:[0: Unknown], [115000: 115 kV], [138000: 138 kV], More
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [300000: 300 kV], [362000: 362 kV], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: High Voltage Arrester
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 2
- assettype: 0
- maintby: 1
- plandevicestatus: 3
- normaldevicestatus: 3
- currentdevicestatus: 3
- winterdevicestatus: 3
- summerdevicestatus: 3
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- phasesnormal: 0
- phasesenergized: 0
- grounding: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 3
Name: High Voltage Controller
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [41: HV Capacitor], [42: Switch and Breaker], More
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: normaldevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: currentdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: winterdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: summerdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: phasesnormal
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasescurrent
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasessummer
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phaseswinter
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasesplan
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasesenergized
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Coded Values:[0: Unknown], [2: 2], [3: 3], More
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Coded Values:[0: Unknown], [115000: 115 kV], [138000: 138 kV], More
- Field Name: maxvoltage
Coded Values:[0: Unknown], [115000: 115 kV], [138000: 138 kV], More
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [300000: 300 kV], [362000: 362 kV], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: High Voltage Controller
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 3
- assettype: 0
- maintby: 1
- plandevicestatus: 3
- normaldevicestatus: 3
- currentdevicestatus: 3
- winterdevicestatus: 3
- summerdevicestatus: 3
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- phasesnormal: 0
- phasesenergized: 0
- grounding: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 4
Name: High Voltage Generation
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [61: Battery], [62: Biomass], More
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: normaldevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: currentdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: winterdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: summerdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: phasesnormal
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasescurrent
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasessummer
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phaseswinter
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasesplan
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasesenergized
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Coded Values:[0: Unknown], [2: 2], [3: 3], More
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Coded Values:[0: Unknown], [115000: 115 kV], [138000: 138 kV], More
- Field Name: maxvoltage
Coded Values:[0: Unknown], [115000: 115 kV], [138000: 138 kV], More
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [300000: 300 kV], [362000: 362 kV], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: remotecontrollerindicator
Coded Values:[0: Unknown], [2: Group 2], [3: Group 3], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: High Voltage Generation
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 4
- assettype: 0
- maintby: 1
- plandevicestatus: 3
- normaldevicestatus: 3
- currentdevicestatus: 3
- winterdevicestatus: 3
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 3
- phasesenergized: 0
- grounding: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 5
Name: High Voltage Line Monitor and Relay
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [80: HV Fault Indicator], [81: HV Instrument Transformer], More
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: normaldevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: currentdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: winterdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: summerdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: phasesnormal
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasescurrent
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasessummer
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phaseswinter
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasesplan
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasesenergized
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Coded Values:[0: Unknown], [2: 2], [3: 3], More
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Coded Values:[0: Unknown], [115000: 115 kV], [138000: 138 kV], More
- Field Name: maxvoltage
Coded Values:[0: Unknown], [115000: 115 kV], [138000: 138 kV], More
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [300000: 300 kV], [362000: 362 kV], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: High Voltage Line Monitor and Relay
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 5
- assettype: 0
- maintby: 1
- plandevicestatus: 3
- normaldevicestatus: 3
- currentdevicestatus: 3
- winterdevicestatus: 3
- summerdevicestatus: 3
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- phasesnormal: 0
- phasesenergized: 0
- grounding: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 6
Name: High Voltage Power Conversion
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [101: Inverter], [102: Rectifier]
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: normaldevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: currentdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: winterdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: summerdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: phasesnormal
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasescurrent
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasessummer
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phaseswinter
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasesplan
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasesenergized
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Coded Values:[0: Unknown], [2: 2], [3: 3], More
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Coded Values:[0: Unknown], [115000: 115 kV], [138000: 138 kV], More
- Field Name: maxvoltage
Coded Values:[0: Unknown], [115000: 115 kV], [138000: 138 kV], More
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [300000: 300 kV], [362000: 362 kV], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: remotecontrollerindicator
Coded Values:[0: Unknown], [1: Grounded Wye], [2: Wye], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: High Voltage Power Conversion
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 6
- assettype: 0
- maintby: 1
- plandevicestatus: 3
- normaldevicestatus: 3
- currentdevicestatus: 3
- winterdevicestatus: 3
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 3
- phasesenergized: 0
- grounding: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 7
Name: High Voltage Power Factor Correcting
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [121: AC Capacitor], [122: AC Wave Trap], More
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: normaldevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: currentdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: winterdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: summerdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: phasesnormal
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasescurrent
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasessummer
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phaseswinter
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasesplan
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasesenergized
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Coded Values:[0: Unknown], [2: 2], [3: 3], More
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Coded Values:[0: Unknown], [115000: 115 kV], [138000: 138 kV], More
- Field Name: maxvoltage
Coded Values:[0: Unknown], [115000: 115 kV], [138000: 138 kV], More
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [300000: 300 kV], [362000: 362 kV], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: High Voltage Power Factor Correcting
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 7
- assettype: 0
- maintby: 1
- plandevicestatus: 3
- normaldevicestatus: 3
- currentdevicestatus: 3
- winterdevicestatus: 3
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 3
- phasesenergized: 0
- grounding: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 8
Name: High Voltage Regulator
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [141: AC Single Phase], [142: AC Three Phase], More
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: normaldevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: currentdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: winterdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: summerdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: phasesnormal
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasescurrent
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasessummer
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phaseswinter
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasesplan
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasesenergized
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Coded Values:[0: Unknown], [2: 2], [3: 3], More
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Coded Values:[0: Unknown], [115000: 115 kV], [138000: 138 kV], More
- Field Name: maxvoltage
Coded Values:[0: Unknown], [115000: 115 kV], [138000: 138 kV], More
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [300000: 300 kV], [362000: 362 kV], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: remotecontrollerindicator
Coded Values:[0: Unknown], [1: Grounded Wye], [2: Wye], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: High Voltage Regulator
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 8
- assettype: 0
- maintby: 1
- plandevicestatus: 3
- normaldevicestatus: 3
- currentdevicestatus: 3
- winterdevicestatus: 3
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 3
- phasesenergized: 0
- grounding: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 9
Name: High Voltage Service
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [161: AC Metering], [162: DC Metering]
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: normaldevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: currentdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: winterdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: summerdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: phasesnormal
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasescurrent
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasessummer
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phaseswinter
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasesplan
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasesenergized
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Coded Values:[0: Unknown], [2: 2], [3: 3], More
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Coded Values:[0: Unknown], [115000: 115 kV], [138000: 138 kV], More
- Field Name: maxvoltage
Coded Values:[0: Unknown], [115000: 115 kV], [138000: 138 kV], More
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [300000: 300 kV], [362000: 362 kV], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: High Voltage Service
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 9
- assettype: 0
- maintby: 1
- plandevicestatus: 3
- normaldevicestatus: 3
- currentdevicestatus: 3
- winterdevicestatus: 3
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 3
- phasesenergized: 0
- grounding: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 10
Name: High Voltage Switch
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [181: AC Circuit Breaker], [182: AC Disconnect], More
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[0: Unknown], [1: Open], [2: Closed]
- Field Name: normaldevicestatus
Inherited
- Field Name: currentdevicestatus
Inherited
- Field Name: winterdevicestatus
Inherited
- Field Name: summerdevicestatus
Inherited
- Field Name: phasesnormal
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasescurrent
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasessummer
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phaseswinter
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasesplan
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasesenergized
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Coded Values:[0: Unknown], [2: 2], [3: 3], More
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Coded Values:[0: Unknown], [115000: 115 kV], [138000: 138 kV], More
- Field Name: maxvoltage
Coded Values:[0: Unknown], [115000: 115 kV], [138000: 138 kV], More
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [300000: 300 kV], [362000: 362 kV], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: remotecontrollerindicator
Coded Values:[0: Unknown], [1: Not Gang Operated], [2: Gang Operated, Phase Operable], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: High Voltage Switch
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 10
- assettype: 0
- maintby: 1
- plandevicestatus: 2
- normaldevicestatus: 2
- currentdevicestatus: 2
- winterdevicestatus: 2
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 2
- phasesenergized: 0
- grounding: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 11
Name: High Voltage Transformer
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [201: AC Single Phase Power], [202: AC Three Phase Power], More
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: normaldevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: currentdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: winterdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: summerdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: phasesnormal
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasescurrent
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasessummer
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phaseswinter
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasesplan
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasesenergized
Coded Values:[0: DeEnergized], [1: III], [2: II], More
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Coded Values:[0: Unknown], [2: 2], [3: 3], More
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Coded Values:[0: Unknown], [115000: 115 kV], [138000: 138 kV], More
- Field Name: maxvoltage
Coded Values:[0: Unknown], [115000: 115 kV], [138000: 138 kV], More
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [300000: 300 kV], [362000: 362 kV], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: remotecontrollerindicator
Coded Values:[0: Unknown], [1: Grounded Wye], [2: Wye], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: High Voltage Transformer
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 11
- assettype: 0
- maintby: 1
- plandevicestatus: 3
- normaldevicestatus: 3
- currentdevicestatus: 3
- winterdevicestatus: 3
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 3
- phasesenergized: 0
- grounding: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 12
Name: Low Voltage Arrester
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [221: LV Overhead Arrester], [222: LV Underground Arrester], More
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: normaldevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: currentdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: winterdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: summerdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: phasesnormal
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasescurrent
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasessummer
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phaseswinter
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasesplan
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasesenergized
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Inherited
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Coded Values:[0: Unknown], [208: 208 V], [240: 240 V], More
- Field Name: maxvoltage
Coded Values:[0: Unknown], [208: 208 V], [240: 240 V], More
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [229: 229 V], [253: 253 V], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: Low Voltage Arrester
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 12
- assettype: 0
- maintby: 1
- plandevicestatus: 3
- normaldevicestatus: 3
- currentdevicestatus: 3
- winterdevicestatus: 3
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 3
- phasesenergized: 0
- numphasesconstructed: 0
- grounding: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 13
Name: Low Voltage Controller
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [241: Controller]
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: normaldevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: currentdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: winterdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: summerdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: phasesnormal
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasescurrent
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasessummer
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phaseswinter
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasesplan
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasesenergized
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Inherited
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Coded Values:[0: Unknown], [208: 208 V], [240: 240 V], More
- Field Name: maxvoltage
Coded Values:[0: Unknown], [208: 208 V], [240: 240 V], More
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [229: 229 V], [253: 253 V], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: Low Voltage Controller
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 13
- assettype: 0
- maintby: 1
- plandevicestatus: 3
- normaldevicestatus: 3
- currentdevicestatus: 3
- winterdevicestatus: 3
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 3
- phasesenergized: 0
- numphasesconstructed: 0
- grounding: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 14
Name: Low Voltage Fuse
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [261: AC Overhead], [262: AC Underground], More
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[0: Unknown], [1: Open], [2: Closed]
- Field Name: normaldevicestatus
Inherited
- Field Name: currentdevicestatus
Inherited
- Field Name: winterdevicestatus
Inherited
- Field Name: summerdevicestatus
Inherited
- Field Name: phasesnormal
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasescurrent
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasessummer
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phaseswinter
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasesplan
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasesenergized
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Inherited
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Coded Values:[0: Unknown], [208: 208 V], [240: 240 V], More
- Field Name: maxvoltage
Coded Values:[0: Unknown], [208: 208 V], [240: 240 V], More
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [229: 229 V], [253: 253 V], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: nominalvoltagelg
Coded Values:[0: Unknown], [120: 120 V], [277: 277 V], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: Low Voltage Fuse
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 14
- assettype: 0
- maintby: 1
- plandevicestatus: 2
- normaldevicestatus: 2
- currentdevicestatus: 2
- winterdevicestatus: 2
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 2
- phasesenergized: 0
- numphasesconstructed: 0
- grounding: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 15
Name: Low Voltage Generation
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [61: Battery], [282: Car Charger], More
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: normaldevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: currentdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: winterdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: summerdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: phasesnormal
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasescurrent
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasessummer
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phaseswinter
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasesplan
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasesenergized
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Inherited
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Coded Values:[0: Unknown], [208: 208 V], [240: 240 V], More
- Field Name: maxvoltage
Coded Values:[0: Unknown], [208: 208 V], [240: 240 V], More
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [229: 229 V], [253: 253 V], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: remotecontrollerindicator
Coded Values:[0: Unknown], [2: Group 2], [3: Group 3], More
- Field Name: nominalvoltagelg
Coded Values:[0: Unknown], [120: 120 V], [277: 277 V], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: Low Voltage Generation
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 15
- assettype: 0
- maintby: 1
- plandevicestatus: 3
- normaldevicestatus: 3
- currentdevicestatus: 3
- winterdevicestatus: 3
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 3
- phasesenergized: 0
- numphasesconstructed: 0
- grounding: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 16
Name: Low Voltage Lighting
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [301: Flood light], [302: Streetlight]
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: normaldevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: currentdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: winterdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: summerdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: phasesnormal
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasescurrent
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasessummer
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phaseswinter
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasesplan
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasesenergized
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Inherited
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Coded Values:[0: Unknown], [208: 208 V], [240: 240 V], More
- Field Name: maxvoltage
Coded Values:[0: Unknown], [208: 208 V], [240: 240 V], More
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [229: 229 V], [253: 253 V], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: remotecontrollerindicator
Coded Values:[0: Unknown], [30: High Pressure Sodium (HPS)], [31: Low Pressure Sodium (LPS)], More
- Field Name: nominalvoltagelg
Coded Values:[0: Unknown], [120: 120 V], [277: 277 V], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: Low Voltage Lighting
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 16
- assettype: 0
- maintby: 1
- plandevicestatus: 3
- normaldevicestatus: 3
- currentdevicestatus: 3
- winterdevicestatus: 3
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 3
- phasesenergized: 0
- numphasesconstructed: 0
- grounding: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 17
Name: Low Voltage Line Monitor and Relay
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [321: LV Fault Indicator], [322: LV Load Monitor], More
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: normaldevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: currentdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: winterdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: summerdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: phasesnormal
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasescurrent
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasessummer
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phaseswinter
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasesplan
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasesenergized
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Inherited
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Coded Values:[0: Unknown], [208: 208 V], [240: 240 V], More
- Field Name: maxvoltage
Coded Values:[0: Unknown], [208: 208 V], [240: 240 V], More
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [229: 229 V], [253: 253 V], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: nominalvoltagelg
Coded Values:[0: Unknown], [120: 120 V], [277: 277 V], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: Low Voltage Line Monitor and Relay
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 17
- assettype: 0
- maintby: 1
- plandevicestatus: 3
- normaldevicestatus: 3
- currentdevicestatus: 3
- winterdevicestatus: 3
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 3
- phasesenergized: 0
- numphasesconstructed: 0
- grounding: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 18
Name: Low Voltage Motor
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [341: LV Single Phase Motor], [342: LV Three Phase Motor]
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: normaldevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: currentdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: winterdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: summerdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: phasesnormal
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasescurrent
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasessummer
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phaseswinter
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasesplan
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasesenergized
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Inherited
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Coded Values:[0: Unknown], [208: 208 V], [240: 240 V], More
- Field Name: maxvoltage
Coded Values:[0: Unknown], [208: 208 V], [240: 240 V], More
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [229: 229 V], [253: 253 V], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: nominalvoltagelg
Coded Values:[0: Unknown], [120: 120 V], [277: 277 V], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: Low Voltage Motor
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 18
- assettype: 0
- maintby: 1
- plandevicestatus: 3
- normaldevicestatus: 3
- currentdevicestatus: 3
- winterdevicestatus: 3
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 3
- phasesenergized: 0
- numphasesconstructed: 0
- grounding: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 19
Name: Low Voltage Network Protection
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [361: Network Protector]
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[0: Unknown], [1: Open], [2: Closed]
- Field Name: normaldevicestatus
Inherited
- Field Name: currentdevicestatus
Inherited
- Field Name: winterdevicestatus
Inherited
- Field Name: summerdevicestatus
Inherited
- Field Name: phasesnormal
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasescurrent
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasessummer
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phaseswinter
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasesplan
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasesenergized
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Inherited
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Coded Values:[0: Unknown], [208: 208 V], [240: 240 V], More
- Field Name: maxvoltage
Coded Values:[0: Unknown], [208: 208 V], [240: 240 V], More
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [229: 229 V], [253: 253 V], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: nominalvoltagelg
Coded Values:[0: Unknown], [120: 120 V], [277: 277 V], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: Low Voltage Network Protection
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 19
- assettype: 0
- maintby: 1
- plandevicestatus: 2
- normaldevicestatus: 2
- currentdevicestatus: 2
- winterdevicestatus: 2
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 2
- phasesenergized: 0
- numphasesconstructed: 0
- grounding: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 20
Name: Low Voltage Power Conversion
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [381: LV Single Phase Inverter], [382: LV Single Phase Rectifier], More
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: normaldevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: currentdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: winterdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: summerdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: phasesnormal
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasescurrent
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasessummer
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phaseswinter
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasesplan
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasesenergized
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Inherited
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Coded Values:[0: Unknown], [208: 208 V], [240: 240 V], More
- Field Name: maxvoltage
Coded Values:[0: Unknown], [208: 208 V], [240: 240 V], More
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [229: 229 V], [253: 253 V], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: nominalvoltagelg
Coded Values:[0: Unknown], [120: 120 V], [277: 277 V], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: Low Voltage Power Conversion
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 20
- assettype: 0
- maintby: 1
- plandevicestatus: 3
- normaldevicestatus: 3
- currentdevicestatus: 3
- winterdevicestatus: 3
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 3
- phasesenergized: 0
- numphasesconstructed: 0
- grounding: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 21
Name: Low Voltage Power Factor Correcting
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [401: Mobile Harmonic Filter], [402: Mobile Reactor], More
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: normaldevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: currentdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: winterdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: summerdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: phasesnormal
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasescurrent
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasessummer
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phaseswinter
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasesplan
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasesenergized
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Inherited
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Coded Values:[0: Unknown], [208: 208 V], [240: 240 V], More
- Field Name: maxvoltage
Coded Values:[0: Unknown], [208: 208 V], [240: 240 V], More
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [229: 229 V], [253: 253 V], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: remotecontrollerindicator
Coded Values:[0: Unknown], [1: Grounded Wye], [2: Wye], More
- Field Name: nominalvoltagelg
Coded Values:[0: Unknown], [120: 120 V], [277: 277 V], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: Low Voltage Power Factor Correcting
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 21
- assettype: 0
- maintby: 1
- plandevicestatus: 3
- normaldevicestatus: 3
- currentdevicestatus: 3
- winterdevicestatus: 3
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 3
- phasesenergized: 0
- numphasesconstructed: 0
- grounding: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 22
Name: Low Voltage Service
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [421: Single Phase Commercial], [422: Single Phase Residential], More
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: normaldevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: currentdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: winterdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: summerdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: phasesnormal
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasescurrent
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasessummer
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phaseswinter
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasesplan
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasesenergized
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Inherited
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Coded Values:[0: Unknown], [208: 208 V], [240: 240 V], More
- Field Name: maxvoltage
Coded Values:[0: Unknown], [208: 208 V], [240: 240 V], More
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [229: 229 V], [253: 253 V], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: nominalvoltagelg
Coded Values:[0: Unknown], [120: 120 V], [277: 277 V], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: Low Voltage Service
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 22
- assettype: 0
- maintby: 1
- plandevicestatus: 3
- normaldevicestatus: 3
- currentdevicestatus: 3
- winterdevicestatus: 3
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 3
- phasesenergized: 0
- numphasesconstructed: 0
- grounding: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 23
Name: Low Voltage Switch
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [441: Overhead AC Load Break], [442: Overhead AC Disconnect], More
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[0: Unknown], [1: Open], [2: Closed]
- Field Name: normaldevicestatus
Inherited
- Field Name: currentdevicestatus
Inherited
- Field Name: winterdevicestatus
Inherited
- Field Name: summerdevicestatus
Inherited
- Field Name: phasesnormal
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasescurrent
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasessummer
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phaseswinter
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasesplan
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasesenergized
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Inherited
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Coded Values:[0: Unknown], [208: 208 V], [240: 240 V], More
- Field Name: maxvoltage
Coded Values:[0: Unknown], [208: 208 V], [240: 240 V], More
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [229: 229 V], [253: 253 V], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: remotecontrollerindicator
Coded Values:[0: Unknown], [1: Not Gang Operated], [2: Gang Operated, Phase Operable], More
- Field Name: nominalvoltagelg
Coded Values:[0: Unknown], [120: 120 V], [277: 277 V], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: Low Voltage Switch
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 23
- assettype: 0
- maintby: 1
- plandevicestatus: 2
- normaldevicestatus: 2
- currentdevicestatus: 2
- winterdevicestatus: 2
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 2
- phasesenergized: 0
- numphasesconstructed: 0
- grounding: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 24
Name: Low Voltage Transformer
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [461: Single Phase], [462: Three Phase]
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: normaldevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: currentdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: winterdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: summerdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: phasesnormal
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasescurrent
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasessummer
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phaseswinter
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasesplan
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasesenergized
Coded Values:[0: De-Energized], [1: c], [2: b], More
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Inherited
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Coded Values:[0: Unknown], [208: 208 V], [240: 240 V], More
- Field Name: maxvoltage
Coded Values:[0: Unknown], [208: 208 V], [240: 240 V], More
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [229: 229 V], [253: 253 V], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: remotecontrollerindicator
Coded Values:[0: Unknown], [1: Grounded Wye], [2: Wye], More
- Field Name: nominalvoltagelg
Coded Values:[0: Unknown], [120: 120 V], [277: 277 V], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: Low Voltage Transformer
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 24
- assettype: 0
- maintby: 1
- plandevicestatus: 3
- normaldevicestatus: 3
- currentdevicestatus: 3
- winterdevicestatus: 3
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 3
- phasesenergized: 0
- numphasesconstructed: 0
- grounding: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 25
Name: Medium Voltage Arrester
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [481: MV Elbow Arrester], [482: MV Line Arrester], More
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: normaldevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: currentdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: winterdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: summerdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: phasesnormal
Inherited
- Field Name: phasescurrent
Inherited
- Field Name: phasessummer
Inherited
- Field Name: phaseswinter
Inherited
- Field Name: phasesplan
Coded Values:[0: DeEnergized], [1: C], [2: B], More
- Field Name: phasesenergized
Inherited
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Inherited
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Inherited
- Field Name: maxvoltage
Inherited
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [8000: 8 kV], [15000: 15 kV], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: nominalvoltagelg
Coded Values:[0: Unknown], [120: 120 V], [277: 277 V], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: Medium Voltage Arrester
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 25
- assettype: 0
- maintby: 1
- plandevicestatus: 3
- normaldevicestatus: 3
- currentdevicestatus: 3
- winterdevicestatus: 3
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 3
- phasesenergized: 0
- numphasesconstructed: 0
- grounding: 0
- nominalvoltage: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 26
Name: Medium Voltage Circuit Breaker
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [501: Isolator Switch], [502: Single Phase Circuit Breaker], More
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[0: Unknown], [1: Open], [2: Closed]
- Field Name: normaldevicestatus
Inherited
- Field Name: currentdevicestatus
Inherited
- Field Name: winterdevicestatus
Inherited
- Field Name: summerdevicestatus
Inherited
- Field Name: phasesnormal
Inherited
- Field Name: phasescurrent
Inherited
- Field Name: phasessummer
Inherited
- Field Name: phaseswinter
Inherited
- Field Name: phasesplan
Coded Values:[0: DeEnergized], [1: C], [2: B], More
- Field Name: phasesenergized
Inherited
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Inherited
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Inherited
- Field Name: maxvoltage
Inherited
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [8000: 8 kV], [15000: 15 kV], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: equipmentconfiguration3
Coded Values:[0: DeEnergized], [1: C], [2: B], More
- Field Name: equipmentconfiguration1
Coded Values:[0: Unknown], [1: Open], [2: Closed]
- Field Name: nominalvoltagelg
Coded Values:[0: Unknown], [120: 120 V], [277: 277 V], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: Medium Voltage Circuit Breaker
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 26
- assettype: 0
- maintby: 1
- plandevicestatus: 2
- normaldevicestatus: 2
- currentdevicestatus: 2
- winterdevicestatus: 2
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 2
- phasesenergized: 0
- numphasesconstructed: 0
- grounding: 0
- nominalvoltage: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 27
Name: Medium Voltage Controller
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [521: MV Capacitor], [522: MV Circuit Breaker], More
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: normaldevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: currentdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: winterdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: summerdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: phasesnormal
Inherited
- Field Name: phasescurrent
Inherited
- Field Name: phasessummer
Inherited
- Field Name: phaseswinter
Inherited
- Field Name: phasesplan
Coded Values:[0: DeEnergized], [1: C], [2: B], More
- Field Name: phasesenergized
Inherited
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Inherited
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Inherited
- Field Name: maxvoltage
Inherited
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [8000: 8 kV], [15000: 15 kV], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: nominalvoltagelg
Coded Values:[0: Unknown], [2400: 2.4 kV], [4800: 4.8 kV], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: Medium Voltage Controller
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 27
- assettype: 0
- maintby: 1
- plandevicestatus: 3
- normaldevicestatus: 3
- currentdevicestatus: 3
- winterdevicestatus: 3
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 3
- phasesenergized: 0
- numphasesconstructed: 0
- grounding: 0
- nominalvoltage: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 28
Name: Medium Voltage Elbow
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [541: Load Break Feedthru], [542: Load Break Junction], More
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[0: Unknown], [1: Open], [2: Closed]
- Field Name: normaldevicestatus
Inherited
- Field Name: currentdevicestatus
Inherited
- Field Name: winterdevicestatus
Inherited
- Field Name: summerdevicestatus
Inherited
- Field Name: phasesnormal
Inherited
- Field Name: phasescurrent
Inherited
- Field Name: phasessummer
Inherited
- Field Name: phaseswinter
Inherited
- Field Name: phasesplan
Coded Values:[0: DeEnergized], [1: C], [2: B], More
- Field Name: phasesenergized
Inherited
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Inherited
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Inherited
- Field Name: maxvoltage
Inherited
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [8000: 8 kV], [15000: 15 kV], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: nominalvoltagelg
Coded Values:[0: Unknown], [2400: 2.4 kV], [4800: 4.8 kV], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: Medium Voltage Elbow
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 28
- assettype: 0
- maintby: 1
- plandevicestatus: 2
- normaldevicestatus: 2
- currentdevicestatus: 2
- winterdevicestatus: 2
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 2
- phasesenergized: 0
- numphasesconstructed: 0
- grounding: 0
- nominalvoltage: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 29
Name: Medium Voltage Fuse
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [561: Bayonet], [562: Fault Limiter], More
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[0: Unknown], [1: Open], [2: Closed]
- Field Name: normaldevicestatus
Inherited
- Field Name: currentdevicestatus
Inherited
- Field Name: winterdevicestatus
Inherited
- Field Name: summerdevicestatus
Inherited
- Field Name: phasesnormal
Inherited
- Field Name: phasescurrent
Inherited
- Field Name: phasessummer
Inherited
- Field Name: phaseswinter
Inherited
- Field Name: phasesplan
Coded Values:[0: DeEnergized], [1: C], [2: B], More
- Field Name: phasesenergized
Inherited
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Inherited
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Inherited
- Field Name: maxvoltage
Inherited
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [8000: 8 kV], [15000: 15 kV], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: nominalvoltagelg
Coded Values:[0: Unknown], [2400: 2.4 kV], [4800: 4.8 kV], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: Medium Voltage Fuse
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 29
- assettype: 0
- maintby: 1
- plandevicestatus: 2
- normaldevicestatus: 2
- currentdevicestatus: 2
- winterdevicestatus: 2
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 2
- phasesenergized: 0
- numphasesconstructed: 0
- grounding: 0
- nominalvoltage: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 30
Name: Medium Voltage Generation
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [61: Battery], [62: Biomass], More
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: normaldevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: currentdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: winterdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: summerdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: phasesnormal
Inherited
- Field Name: phasescurrent
Inherited
- Field Name: phasessummer
Inherited
- Field Name: phaseswinter
Inherited
- Field Name: phasesplan
Coded Values:[0: DeEnergized], [1: C], [2: B], More
- Field Name: phasesenergized
Inherited
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Inherited
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Inherited
- Field Name: maxvoltage
Inherited
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [8000: 8 kV], [15000: 15 kV], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: remotecontrollerindicator
Coded Values:[0: Unknown], [2: Group 2], [3: Group 3], More
- Field Name: nominalvoltagelg
Coded Values:[0: Unknown], [2400: 2.4 kV], [4800: 4.8 kV], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: Medium Voltage Generation
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 30
- assettype: 0
- maintby: 1
- plandevicestatus: 3
- normaldevicestatus: 3
- currentdevicestatus: 3
- winterdevicestatus: 3
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 3
- phasesenergized: 0
- numphasesconstructed: 0
- grounding: 0
- nominalvoltage: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 31
Name: Medium Voltage Line Monitor and Relay
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [601: Fault Indicator], [602: Instrument Transformer], More
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: normaldevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: currentdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: winterdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: summerdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: phasesnormal
Inherited
- Field Name: phasescurrent
Inherited
- Field Name: phasessummer
Inherited
- Field Name: phaseswinter
Inherited
- Field Name: phasesplan
Coded Values:[0: DeEnergized], [1: C], [2: B], More
- Field Name: phasesenergized
Inherited
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Inherited
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Inherited
- Field Name: maxvoltage
Inherited
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [8000: 8 kV], [15000: 15 kV], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: nominalvoltagelg
Coded Values:[0: Unknown], [2400: 2.4 kV], [4800: 4.8 kV], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: Medium Voltage Line Monitor and Relay
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 31
- assettype: 0
- maintby: 1
- plandevicestatus: 3
- normaldevicestatus: 3
- currentdevicestatus: 3
- winterdevicestatus: 3
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 3
- phasesenergized: 0
- numphasesconstructed: 0
- grounding: 0
- nominalvoltage: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 32
Name: Medium Voltage Motor and Pump
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [621: Single Phase Motor], [622: Single Phase Pump], More
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: normaldevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: currentdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: winterdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: summerdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: phasesnormal
Inherited
- Field Name: phasescurrent
Inherited
- Field Name: phasessummer
Inherited
- Field Name: phaseswinter
Inherited
- Field Name: phasesplan
Coded Values:[0: DeEnergized], [1: C], [2: B], More
- Field Name: phasesenergized
Inherited
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Inherited
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Inherited
- Field Name: maxvoltage
Inherited
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [8000: 8 kV], [15000: 15 kV], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: nominalvoltagelg
Coded Values:[0: Unknown], [2400: 2.4 kV], [4800: 4.8 kV], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: Medium Voltage Motor and Pump
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 32
- assettype: 0
- maintby: 1
- plandevicestatus: 3
- normaldevicestatus: 3
- currentdevicestatus: 3
- winterdevicestatus: 3
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 3
- phasesenergized: 0
- numphasesconstructed: 0
- grounding: 0
- nominalvoltage: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 33
Name: Medium Voltage Power Conversion
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [412: Wave Trap], [641: Single Phase Inverter], More
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: normaldevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: currentdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: winterdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: summerdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: phasesnormal
Inherited
- Field Name: phasescurrent
Inherited
- Field Name: phasessummer
Inherited
- Field Name: phaseswinter
Inherited
- Field Name: phasesplan
Coded Values:[0: DeEnergized], [1: C], [2: B], More
- Field Name: phasesenergized
Inherited
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Inherited
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Inherited
- Field Name: maxvoltage
Inherited
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [8000: 8 kV], [15000: 15 kV], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: nominalvoltagelg
Coded Values:[0: Unknown], [2400: 2.4 kV], [4800: 4.8 kV], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: Medium Voltage Power Conversion
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 33
- assettype: 0
- maintby: 1
- plandevicestatus: 3
- normaldevicestatus: 3
- currentdevicestatus: 3
- winterdevicestatus: 3
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 3
- phasesenergized: 0
- numphasesconstructed: 0
- grounding: 0
- nominalvoltage: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 34
Name: Medium Voltage Power Factor Correcting
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [401: Mobile Harmonic Filter], [402: Mobile Reactor], More
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: normaldevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: currentdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: winterdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: summerdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: phasesnormal
Inherited
- Field Name: phasescurrent
Inherited
- Field Name: phasessummer
Inherited
- Field Name: phaseswinter
Inherited
- Field Name: phasesplan
Coded Values:[0: DeEnergized], [1: C], [2: B], More
- Field Name: phasesenergized
Inherited
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Inherited
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Inherited
- Field Name: maxvoltage
Inherited
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [8000: 8 kV], [15000: 15 kV], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: remotecontrollerindicator
Coded Values:[0: Unknown], [1: Grounded Wye], [2: Wye], More
- Field Name: nominalvoltagelg
Coded Values:[0: Unknown], [2400: 2.4 kV], [4800: 4.8 kV], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: Medium Voltage Power Factor Correcting
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 34
- assettype: 0
- maintby: 1
- plandevicestatus: 3
- normaldevicestatus: 3
- currentdevicestatus: 3
- winterdevicestatus: 3
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 3
- phasesenergized: 0
- numphasesconstructed: 0
- grounding: 0
- nominalvoltage: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 35
Name: Medium Voltage Regulator
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [681: Overhead Single Phase VR], [683: Overhead Three Phase VR], More
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: normaldevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: currentdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: winterdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: summerdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: phasesnormal
Inherited
- Field Name: phasescurrent
Inherited
- Field Name: phasessummer
Inherited
- Field Name: phaseswinter
Inherited
- Field Name: phasesplan
Coded Values:[0: DeEnergized], [1: C], [2: B], More
- Field Name: phasesenergized
Inherited
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Inherited
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Inherited
- Field Name: maxvoltage
Inherited
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [8000: 8 kV], [15000: 15 kV], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: remotecontrollerindicator
Coded Values:[0: Unknown], [1: Grounded Wye], [2: Wye], More
- Field Name: nominalvoltagelg
Coded Values:[0: Unknown], [2400: 2.4 kV], [4800: 4.8 kV], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: Medium Voltage Regulator
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 35
- assettype: 0
- maintby: 1
- plandevicestatus: 3
- normaldevicestatus: 3
- currentdevicestatus: 3
- winterdevicestatus: 3
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 3
- phasesenergized: 0
- numphasesconstructed: 0
- grounding: 0
- nominalvoltage: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 36
Name: Medium Voltage Service
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [701: Primary Meter - Industrial Customer], [702: Primary Meter - Utility Customer], More
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: normaldevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: currentdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: winterdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: summerdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: phasesnormal
Inherited
- Field Name: phasescurrent
Inherited
- Field Name: phasessummer
Inherited
- Field Name: phaseswinter
Inherited
- Field Name: phasesplan
Coded Values:[0: DeEnergized], [1: C], [2: B], More
- Field Name: phasesenergized
Inherited
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Inherited
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Inherited
- Field Name: maxvoltage
Inherited
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [8000: 8 kV], [15000: 15 kV], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: nominalvoltagelg
Coded Values:[0: Unknown], [2400: 2.4 kV], [4800: 4.8 kV], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: Medium Voltage Service
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 36
- assettype: 0
- maintby: 1
- plandevicestatus: 3
- normaldevicestatus: 3
- currentdevicestatus: 3
- winterdevicestatus: 3
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 3
- phasesenergized: 0
- numphasesconstructed: 0
- grounding: 0
- nominalvoltage: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 37
Name: Medium Voltage Switch
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [721: Cabinet Bypass], [722: Cabinet Switch], More
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[0: Unknown], [1: Open], [2: Closed]
- Field Name: normaldevicestatus
Inherited
- Field Name: currentdevicestatus
Inherited
- Field Name: winterdevicestatus
Inherited
- Field Name: summerdevicestatus
Inherited
- Field Name: phasesnormal
Inherited
- Field Name: phasescurrent
Inherited
- Field Name: phasessummer
Inherited
- Field Name: phaseswinter
Inherited
- Field Name: phasesplan
Coded Values:[0: DeEnergized], [1: C], [2: B], More
- Field Name: phasesenergized
Inherited
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Inherited
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Inherited
- Field Name: maxvoltage
Inherited
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [8000: 8 kV], [15000: 15 kV], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: remotecontrollerindicator
Coded Values:[0: Unknown], [1: Not Gang Operated], [2: Gang Operated, Phase Operable], More
- Field Name: nominalvoltagelg
Coded Values:[0: Unknown], [2400: 2.4 kV], [4800: 4.8 kV], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: Medium Voltage Switch
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 37
- assettype: 0
- maintby: 1
- plandevicestatus: 2
- normaldevicestatus: 2
- currentdevicestatus: 2
- winterdevicestatus: 2
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 2
- phasesenergized: 0
- numphasesconstructed: 0
- grounding: 0
- nominalvoltage: 0
- maxvoltage: 0
- lifecyclestatus: 8
ID: 38
Name: Medium Voltage Transformer
Domains:
- Field Name: assettype
Coded Values:[0: Unknown], [204: Grounding Transformer], [782: Mobile Single Phase], More
- Field Name: associationstatus
Inherited
- Field Name: issubnetworkcontroller
Inherited
- Field Name: isconnected
Inherited
- Field Name: tiername
Inherited
- Field Name: plandevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: normaldevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: currentdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: winterdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: summerdevicestatus
Coded Values:[3: Active], [4: Inactive]
- Field Name: phasesnormal
Inherited
- Field Name: phasescurrent
Inherited
- Field Name: phasessummer
Inherited
- Field Name: phaseswinter
Inherited
- Field Name: phasesplan
Coded Values:[0: DeEnergized], [1: C], [2: B], More
- Field Name: phasesenergized
Inherited
- Field Name: phasessubstituted
Inherited
- Field Name: phasefrequency
Inherited
- Field Name: numphasesconstructed
Inherited
- Field Name: grounding
Inherited
- Field Name: nominalvoltage
Inherited
- Field Name: addpowerrating
Coded Values:[0: Unknown], [500: 0.5 kVA], [1000: 1.0 kVA], More
- Field Name: maxvoltage
Inherited
- Field Name: maxoperatingvoltage
Coded Values:[0: Unknown], [8000: 8 kV], [15000: 15 kV], More
- Field Name: lifecyclestatus
Coded Values:[0: Unknown], [1: Proposed], [2: Approved], More
- Field Name: powerrating3
Coded Values:[0: Unknown], [208: 208 V], [240: 240 V], More
- Field Name: remotecontrollerindicator
Coded Values:[0: Unknown], [1: Grounded Wye], [2: Wye], More
- Field Name: nominalvoltagelg
Coded Values:[0: Unknown], [2400: 2.4 kV], [4800: 4.8 kV], More
- Field Name: spatialsource
Inherited
- Field Name: spatialconfidence
Inherited
- Field Name: ownedby
Inherited
- Field Name: maintby
Inherited
- Field Name: symbolrotation
Inherited
Templates:
Name: Medium Voltage Transformer
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- assetgroup: 38
- assettype: 0
- maintby: 1
- plandevicestatus: 3
- normaldevicestatus: 3
- currentdevicestatus: 3
- winterdevicestatus: 3
- spatialsource: 0
- spatialconfidence: 0
- ownedby: 1
- symbolrotation: 0
- terminalconfiguration: Default
- summerdevicestatus: 3
- phasesenergized: 0
- numphasesconstructed: 0
- grounding: 0
- nominalvoltage: 0
- maxvoltage: 0
- lifecyclestatus: 8
Is Data Versioned: false
Has Contingent Values: false
Supports Rollback On Failure Parameter: true
Last Edit Date: 3/8/2022 10:31:58 PM
Schema Last Edit Date: 3/8/2022 10:31:58 PM
Data Last Edit Date: 3/8/2022 10:31:58 PM
Supported Operations:
Query
Query Pivot
Query Top Features
Query Analytic
Query Bins
Add Features
Update Features
Delete Features
Apply Edits
Calculate
Generate Renderer
Validate SQL
Get Estimates
ConvertFormat